Processing. Please wait. Brand: Grandaire Save Listing| Email Listing | Share Product Name: GRANDAIRE WCH4484GKB WAHL484B - 4 Ton SEER 14 Heat Pump Split System Item#: WCH4484GKB WAHL484B Your Price: Email For Price Click Here Choose QTY: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Required Product Details Manuals Video Warranty Shipping Info Returns / Policy Ask A Question Product Details - WCH4484GKB WAHL484B DESCRIPTION HEAT PUMP EFFICIENT 14 SEER 1-1/2 THRU 5 TONS SPLIT SYSTEM ENVIRONMENTALLY SOUND R-410A REFRIGERANT 208 / 230 Volt, 1-phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors on all models Suction line accumulator factory installed Integrated solid state control with Time-Temperature Defrost High and Low pressure switches Copper tube / aluminum fin coil EASY TO INSTALL AND SERVICE Easy Access service valves on all models External high and low refrigerant service ports Only two screws to access control panel Factory charged with R-410A refrigerant BUILT TO LAST Painted cabinet finish over galvanized steel Coated inlet grille with 3/8” (10mm) grille spacing for extra protection (hail guard) SPECIFICATIONS WEIGHT 225.0000 Pound (lb.) WIDTH 31.1875 Inches (in) HEIGHT 28.4375 Inches (in) COUNTRY OF ORIGIN USA UPC OR BARCODE 1PWCH4484GKB HAZARDOUS MATERIAL No EPA CERT REQUIRED No LENGTH 31.1875 Inches (in) BRAND GrandAire EQUIPMENT TYPE Heat Pump TONNAGE 4 REFRIGERANT R-410a VOLTAGE 208-230 VAC PHASE Single DESCRIPTION Multiposition Air Handler • 1.5 Thru 5 Tons L = Aluminum Tube, Aluminum Fin Evaporator M = Copper Tube, Aluminum Fin Evaporator T = Tin Coated Copper Tube, Aluminum Fin Evaporator ALL MODELS 1-1/2 thru 5 tons Available for environmentally sound R-410A systems Factory installed TXV metering device Sweat connections Primary and secondary drain fittings Multiple electrical entry locations Time delay relay (TDR) Field installed heater packages from 5 kW - 30 kW available separately HUD approved for manufactured housing 208/230-1-60 supply voltage Units tested and certified by manufacturer to achieve a 2% or less leakage rate at 1.0 inch water column 1 inch thick insulation with R value of 4.2 Filter (washable) available as accessory ECM 5-speed motor Multiposition installation - upflow or horizontal left standard, horizontal right with minor modification (field convertible to downflow with available accessory kit) Low voltage circuit protective fuse (3amp) inline on wire harness No Heat (Plug) Kit factory installed SPECIFICATIONS WEIGHT 157.0000 Pound (lb.) WIDTH 21.1250 Inches (in) HEIGHT 49.6250 Inches (in) COUNTRY OF ORIGIN USA UPC OR BARCODE 1PWAHL484B HAZARDOUS MATERIAL No EPA CERT REQUIRED No LENGTH 22.0625 Inches (in) BRAND GrandAire EQUIPMENT TYPE Heat Pump TONNAGE 4 REFRIGERANT R-410a AIR FLOW Multi-Position VOLTAGE 208-230 VAC PHASE Single Your Phone Number : Enter Your Phone Number Your Email : Enter Your Email Not valid email address What is your message about : - Select One - Sales Questions General Support Technical Support Webmaster Please select your message about What Is The Status Of Your Project? : - Select One - Ready To Buy Planning/Budgeting Just Curious/Not Buying Anytime Soon Please select status of your project Type your name and message here : Verification Code : 4 + 8 Send Shop for Grandaire and browse manuals and details of WCH4484GKB WAHL484B Vent Cleaning Shoreline, WA Air Conditioner Repairs Dubuque, IA HVAC Installation Tacoma, WA Air Conditioner Repairs Yuma, AZ Commercial AC Company Norwalk, CT Licensed Electrician Portland, OR Top Watch This Item Your Phone Number: Your Email: Message here: Make an offer Quantity you would like to buy: 1 2 3 4 5 6 7 8 9 10 How much would you like to pay for each unit: Type your Message: Shipping Address: URL of the website where you saw cheaper price Or better deal: Your email address: Your phone number: E-mail a friend about this item Your friend email: Your Email: Message here: Email For Price Your Phone Number: Your Email: Shipping Zip Code: How soon do you need this product?: Immidiately Within a week Within couple of months Just looking for price Message here:
Brand: Grandaire Save Listing| Email Listing | Share Product Name: GRANDAIRE WCH4484GKB WAHL484B - 4 Ton SEER 14 Heat Pump Split System Item#: WCH4484GKB WAHL484B Your Price: Email For Price Click Here Choose QTY: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Required
Product Details Manuals Video Warranty Shipping Info Returns / Policy Ask A Question Product Details - WCH4484GKB WAHL484B DESCRIPTION HEAT PUMP EFFICIENT 14 SEER 1-1/2 THRU 5 TONS SPLIT SYSTEM ENVIRONMENTALLY SOUND R-410A REFRIGERANT 208 / 230 Volt, 1-phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors on all models Suction line accumulator factory installed Integrated solid state control with Time-Temperature Defrost High and Low pressure switches Copper tube / aluminum fin coil EASY TO INSTALL AND SERVICE Easy Access service valves on all models External high and low refrigerant service ports Only two screws to access control panel Factory charged with R-410A refrigerant BUILT TO LAST Painted cabinet finish over galvanized steel Coated inlet grille with 3/8” (10mm) grille spacing for extra protection (hail guard) SPECIFICATIONS WEIGHT 225.0000 Pound (lb.) WIDTH 31.1875 Inches (in) HEIGHT 28.4375 Inches (in) COUNTRY OF ORIGIN USA UPC OR BARCODE 1PWCH4484GKB HAZARDOUS MATERIAL No EPA CERT REQUIRED No LENGTH 31.1875 Inches (in) BRAND GrandAire EQUIPMENT TYPE Heat Pump TONNAGE 4 REFRIGERANT R-410a VOLTAGE 208-230 VAC PHASE Single DESCRIPTION Multiposition Air Handler • 1.5 Thru 5 Tons L = Aluminum Tube, Aluminum Fin Evaporator M = Copper Tube, Aluminum Fin Evaporator T = Tin Coated Copper Tube, Aluminum Fin Evaporator ALL MODELS 1-1/2 thru 5 tons Available for environmentally sound R-410A systems Factory installed TXV metering device Sweat connections Primary and secondary drain fittings Multiple electrical entry locations Time delay relay (TDR) Field installed heater packages from 5 kW - 30 kW available separately HUD approved for manufactured housing 208/230-1-60 supply voltage Units tested and certified by manufacturer to achieve a 2% or less leakage rate at 1.0 inch water column 1 inch thick insulation with R value of 4.2 Filter (washable) available as accessory ECM 5-speed motor Multiposition installation - upflow or horizontal left standard, horizontal right with minor modification (field convertible to downflow with available accessory kit) Low voltage circuit protective fuse (3amp) inline on wire harness No Heat (Plug) Kit factory installed SPECIFICATIONS WEIGHT 157.0000 Pound (lb.) WIDTH 21.1250 Inches (in) HEIGHT 49.6250 Inches (in) COUNTRY OF ORIGIN USA UPC OR BARCODE 1PWAHL484B HAZARDOUS MATERIAL No EPA CERT REQUIRED No LENGTH 22.0625 Inches (in) BRAND GrandAire EQUIPMENT TYPE Heat Pump TONNAGE 4 REFRIGERANT R-410a AIR FLOW Multi-Position VOLTAGE 208-230 VAC PHASE Single Your Phone Number : Enter Your Phone Number Your Email : Enter Your Email Not valid email address What is your message about : - Select One - Sales Questions General Support Technical Support Webmaster Please select your message about What Is The Status Of Your Project? : - Select One - Ready To Buy Planning/Budgeting Just Curious/Not Buying Anytime Soon Please select status of your project Type your name and message here : Verification Code : 4 + 8 Send Shop for Grandaire and browse manuals and details of WCH4484GKB WAHL484B Vent Cleaning Shoreline, WA Air Conditioner Repairs Dubuque, IA HVAC Installation Tacoma, WA Air Conditioner Repairs Yuma, AZ Commercial AC Company Norwalk, CT Licensed Electrician Portland, OR Top